ORIGINAL ARTICLE
Year : 2016  |  Volume : 10  |  Issue : 3  |  Page : 324-329

Effectiveness of nocturnal oximetry in predicting obstructive sleep apnea hypopnea syndrome: value of nocturnal oximetry in prediction of obstructive sleep apnea hypopnea syndrome


1 Chest Medicine Department, Faculty of Medicine, Mansoura University, Egypt
2 Chest Department, Mansoura University Hospital, Mansoura, Egypt

Correspondence Address:
Lucy A Suliman
Samia El Gamal Street, Elmansoura 23315
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1687-8426.193647

Rights and Permissions

Background Polysomnography (PSG) is the gold standard for diagnosing obstructive sleep apnea (OSA). However, it is time-consuming, expensive and requires technical expertise. Thus, a number of alternatives to PSG have been proposed. The present study was conducted to analyse the sensitivity, specificity and accuracy of night oximetry as a diagnostic tool in patients suspected to have sleep apnea hypopnea syndrome (SAHS), and to reduce the number of saved PSGs. Patients and methods In total, 40 middle-aged patients clinically suspected to have Obstructive Sleep Apnea Hypopnea Syndrome (OSAHS) were included in the study. They were classified into two groups: group I (the SAHS group), comprising 33 patients with apnea hypopnea index greater than or equal to 5; and group II (the non-SAHS group), comprising seven patients with apnea hypopnea index l than 5. All patients were subjected to the following: (a) OSA screening questionnaire; (b) BMI in kg/m2, neck circumference in cm, and cardiac, chest and ENT examinations; (c) investigation in the form of arterial blood gases, chest radiograph, ECG and spirometry; and (d) full PSG and overnight oximetry, which were carried out simultaneously. Results The baseline values of O2 saturation derived from PSG and oximetry were 93.33±2.32 and 91.50±2.79, respectively. The overnight oxygen desaturation index of oximetry was significantly lower in the SAHS group. Minimal SpO2 of PSG was significantly lower in the SAHS group. The best predicted cutoff value of overnight pulse oximetry using oxygen desaturation index for mild to moderate OSA patient diagnosis was 14.78, with 87.88% sensitivity and 88.71% specificity. However, the optimal cutoff value for severe OSA diagnosis was 52.55, with 86.67% sensitivity and 96% specificity. Conclusion Overnight pulse oximetry may be considered a diagnostic tool in patients suspected to have SAHS, with excellent diagnostic sensitivity, specificity and accuracy, which increased with severity.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1180    
    Printed13    
    Emailed0    
    PDF Downloaded149    
    Comments [Add]    

Recommend this journal